	POD_2.ini
		For: 		Codesoft driver (POD.PRN)
		Where: 		Codesoft directory
--------------------------------------

[GLOBALVAR]
PassGeneralIni1="4213"
PassGeneralIni2="999999"
NetworkNumber=9
NetworkPresence=0
;SendOnlyUpdate=Always
;DisplayCounterBox=No
PrinterHasToBeTheSame=Yes
ReloadSettings=Yes
ReloadSettingsFrom=c:\dataSaved.ini
UseSystemVariables=Yes
FormulasReferToVariables=Yes
PrintToGlobalVariables=Yes
;VariablesBack=Counters,Status
;VariablesBack=Counters,Status,Variables,Dates,All
WaitEscReadyDone=Yes


[HideOptionsInDialogBox]
DISPLAY_ButtonDefault=1
DISPLAY_ButtonOptimize=1
DISPLAY_CheckPrinterStatus=1
DISPLAY_CompressionImage=1
DISPLAY_DestinationMemory=1
DISPLAY_FormatActived=1
DISPLAY_ImmediatPrinting=1
DISPLAY_InfinitePrinting=1
DISPLAY_Network=1
DISPLAY_ReloadImages=1
DISPLAY_SendModifiedData=1
DISPLAY_StoreFixedImages=1
DISPLAY_TimeOut=1

--------------------------------------
WaitEscReadyDone:
  .=Yes: Codesoft waits the signal "<ESC> READY" or "DONE" from
      the printer after printing  (interesting on using ActiveX, the developper
      does not need to manage this signal from the printer)
  .=No: no action; except on Merge (as it was)
VariablesBack=Counters,Status,Variables,Dates,All
  use with SYSUPMOD=4; see Variables back from the printer
  after each printing cycle 
  instead of <Esc> DONE or <Esc> READY, the printer sends back with:
    .<Status>: the current printer status information
    .<Counters>: all counters name and value
    .<Variables>: all variables name and value
    .<Dates>: all dates fields
    .<All>: everything mentioned above this line
PrintToGlobalVariables:
  .=Yes: force to print to Global variables instead of local variables
        Format:
        Esc 0 G E variableNameOn10 ...data...
        
        Format:
        Esc 0 F ...
        ...
        Esc 0 T Arial ...  \0variableNameOn10\0
        ...
        Esk 0 K
  .Else: default value
       Codesoft sends the Variables as Locals (ESC E)
FormulasReferToVariables:
  .=No: the driver keeps the original value calculated in Codesoft.
         (without references to any variables)
  .Else: default value
         formula is based on the defined variables (if present).
ReloadSettings:
  -possible to force the driver to read
    all settings from user.ini before Printing and Displaying 
    the settings dialog  box.
ReloadSettingsFrom=c:\dataSaved.ini
  -possible to force the driver to read this as a User.ini file
  -enter a Full file path name
UseSystemVariables:
  -possible to send several System variables
   The system variables used are in User.ini, field: SystemVariables
   ex:
   [OD_53S,->COM9:]
   ...
   SystemVariables=SYSRIBTFR 95,SYSLANG 2

PassGeneralIni1:
PassGeneralIni2:
  passwords used in dialog box
NetworkNumber:   
  last network number used by the Codesoft   
NetworkPresence=0
  values: 
    .0 if no network set
    .1 else
SendOnlyUpdate
  values:
    .=Always: if we just send the updated data to the external device
       specially used with the 'Generic' printer
       Warning: print ALL objects on FIRST print only. Use this Generic 
            printer when managing from an activeX application for example
    .Else: we send all data
DisplayCounterBox=No
  values:
    .=Yes: a box is displaid before printing to get all information 
           about counters.
    .Else: All data from the Standard counter dialog box are used.
PrinterHasToBeTheSame=Yes
    .=Yes: the driver checks that the printer installed and the external 
           device are the same.
    .Else: no check

DISPLAY_ButtonDefault=1
DISPLAY_ButtonOptimize=1
DISPLAY_CheckPrinterStatus=1
DISPLAY_CompressionImage=1
DISPLAY_DestinationMemory=1
DISPLAY_FormatActived=1
DISPLAY_ImmediatPrinting=1
DISPLAY_InfinitePrinting=1
DISPLAY_Network=1
DISPLAY_ReloadImages=1
DISPLAY_SendModifiedData=1
DISPLAY_StoreFixedImages=1
DISPLAY_TimeOut=1
	Display or not the options in the printer driver dialog box